您的瀏覽器版本已過時。我們建議您更新瀏覽器到最新版本。

 

Floor Type Autoclave Sterilizer

Purpose:

The steam sterilizer is a highly safe sterilizing product with stable function, suitable for the sterilization of instrument, cloth, glassware and liquid in major hospitals, clinics, biochemical research laboratories etc.

The inner chamber is made from #304 stainless steel, while the outer chamber and the door cover are made from #304[p1]  stainless steel. The outer layer is separated by thermal insulation wool for heat preservation. The outside is covered by rectangular stainless steel sheets which offer a more aesthetic appearance and heat preservation.

Stainless steel door with radial lever can effectively lock the door cover tightly and prevent steam leakage

Silicone door gasket is heat-resistant, durable, and without deformation.

Indicator: Displays the processing status of the sterilization process according to its sequence when the machine is operating.

 

Practical Sterilization Function:

1. The preset vacuum function is able to shorten the sterilization time.

2. Vacuum drying function is able to quickly remove the unwanted moisture, and to reach the Bowie Dick test criteria.

3. Cloth/apparatus/liquid Sterilization Functional Switch Mode can be selected to switch according to different kinds of                 materials being sterilized.

4. Auto Water Supply Device: Electrical control system is able to detect and sense the water volume automatically. Upon             insufficient water volume, it will supply to high water level automatically. Use soft water purification equipment can                 prolong the life cycle of the sterilizer.

 

Safety Devices:

1. Auto Power-Off Protection Device for water shortage: When water runs out, the electrical control system will automatically     cut off the heating power to prevent heating device from overheating, dry-out or even meltdown.

2. Pressure Controller: The maximum pressure in the boiler is set to 2.2 ± 0.1 kg/cm2. When the pressure reaches the                 set value, the heating power will be automatically cut off to prevent the pressure from rising.

3. Safety Valve: When the pressure reaches 2.8kg/cm2, it will start a rapid exhaust of steam and release the pressure from         the chamber.

4. Pressure Lock: When the pressure of inner chamber exceeds 0.2kg/cm2, the clutch will be locked automatically, and the          door cover will not be able to open, in order to keep the operator safe.

5. Safety Switch of Door Cover: When the door cover is opened, the steam in the outer chamber is unable to enter the inner       chamber. It cannot be operated normally unless the door cover is closed tightly.

 

Simple Operation Interface:

1. Digital LED electronic timer is able to control the working hours of sterilization and drying precisely within the range of 0-       99 minutes

2. Digital LED electronic temperature controller is able to set the required working temperature quickly, and show the                 current temperature status of inner chamber. The highest setting temperature is 134°C (218.47°F)

3. The temperature recorder can monitor and record the time and temperature during the whole process of sterilization

4. The pressure gauge of inner and outer chambers is able to clearly show the current working temperature status of                   interior of sterilizer

5. The opening and closing of turning type door cover is easy to operate.

 

The highest sterilization temperature is 134˚C (218.47°F), and the pressure value for sterilization is able to reach up to 2.2kg/cm2 (2.16bar or 31.29psi)

Heating device with high power takes 20 minutes to complete sterilization under 121°C, or 15 minutes under 132°C.

 

The preparation steps for sterilization function are shown as following:

Fully-automatic operation-

Put the items inside, and close the door cover ► Set mode (cloth/apparatus/liquid)/temperature/time ► Turn on the power / Activate the switch ► Supply water automatically ► Heating ► Preset vacuum for 3 times ► Sterilizing ► Steam exhaust for inner chamber ► Vacuum drying ► Completion

 

Function list

Function \ operating system 

Automatic and vacuum drying function

 Function \ operating system 

Automatic and vacuum drying function

Timer

99Minutes x 2pcs

Chamber Design

ASME STANDARD

steam exhaust valve outer chamber

YES

Chamber material stainless steel #304(optioned#316)

Optional

Dry valve inner chamber

YES

6 Points

Temperature Recorder

CAN BE OPTIONED

water Level Control & Protection

YES

safety door lock activated by pressure

YES

Optional Accessories

ST.ST. BASKET TRANSPORTATION (TRAY x 2, FRAME x 1)

Preheating function

YES

Auto water filling

YES

standard Accessories

ST.ST. #304 TRAY x 1 pcs

sterilization function

YES

Construction

ST.ST. #304 HOUSING FRAME, DOOR, CHAMBER AND JACKET

Low water indication cut-off

YES

Pressure Control Switch

YES

control System

TEMPERATURE DISPLAY TEMPERATURE CONTROL SYSTEM

Temperature Control Switch

YES

Pre-Vacuum Function

YES

Safety Device

PRESSURE PROTECTION SWITCH TEMPERATURE CONTROL SWITCH WATER LEVEL CONTROL SYSTEM LOW WATER INDICATION/CUT-OFF SAFETY VALVE, DOOR ALARM PRESSURE DOOR AUTO-LOCK Emergency off, EMO

Dry-Vacuum Function

YES

Glass & Liquid sterilization function

YES

Using Temperature

121°C~134°C (1,1-2.2kg/cm2) (250°F~273°F) ADJUSTABLE

Design Temperature

140°C

Life Time

7 YEARS

 

Model

External DIA L.W.H.(cm)

Chamber ØxD(cm)

Capacity (Liter)

Power Consumption (Kw)

Max Sterilization Temperature (°C)

Operate Pressure(kg/cm2)

N.W. (Kg)

TC-750

163x105x206

75x120

530 L

24

134 ±2

2.4 ± 0.1

415

TC-615

183x90x190

60x150

424L

24

134 ±2

2.4 ± 0.1

355

TC-612

153x90x190

60x120

339L

18

134 ±2

2.4 ± 0.1

300

TC-600

135x90x190

60x100

283L

13

134 ±2

2.4 ± 0.1

255

TC-500

135x78x185

50x100

196L

12

132 ±2

2.4 ± 0.1

215

TC-459

110x70x164

45x90

143L

9

132 ±2

2.2 ± 0.1

170

TC-409

109x65x160

40x90

113L

9

132 ±2

2.2 ± 0.1

140

TC-336

82x56x158

33x66

56L

6

132 ±2

2.2 ± 0.1

97

 

AC 220V1P, 220V 3P, 380V 3P, 50/60Hz (please specify when ordering) TC-500, TC-612, TC-600, TC-615, TC-750 : 380V 3P phase only

AMPERE conversion formula

(1-phase → 3-phase) Wattagel Voltage I 1.732 = Amp for 3-phase